Chapter 7 Application Tutorial Installation and Operation Manual
7-46 WiMAX Backhauling Opposite RICi-4T1 Egate-100 Ver. 4.0
The selected cell is highlighted and the value is displayed in the
Change Cell field.
3. Select Change Cell, and enter 192.188.10.11 for the selected network
manager.
³ To configure the system clock source:
1. Navigate to the master clock source menu (Main Menu>Configuration>
System >Clock Source>Master Clock) and configure the parameter values as
illustrated in
Figure
7-62
.
2. Navigate to the fallback clock source menu (Main Menu>Configuration>
System>Clock Source > Fallback Clock) and configure the parameter values as
illustrated in
Figure
7-63
.
Egate-100
…Configuration> System> Clock Source> Master Clock
1. Source > (Rx Clock)
2. Wait to Restore(sec)[0 - 720] ... (300)
3. Port Number [1 - 3] ... (1)
>
Please select item <1 to 3>
ESC-prev.menu; !-main menu; &-exit
Figure
7-62. Configuring Master Clock Source
Egate-100
Main Menu> Configuration> System> Clock Source> Fallback Clock
1. Source > (Internal)
2. Wait to Restore (sec)[0 - 720]... (300)
3. Port Number [1 - 3] ... (2)
Please select item <1 to 3>
ESC-prev.menu; !-main menu; &-exit
Figure
7-63. Configuring Fallback Clock Source
Setting Ethernet Parameters
The Gigabit Ethernet ports must be configured for operation if the default values
are not suitable for the application.
³ To configure the Gigabit Ethernet interface:
Display the Ethernet Menu (Main Menu > Configuration > Physical Layer >
Ethernet), and configure the following for both Gigabit Ethernet links
according to your application requirements:
Autonegotiation
Max capability.