Chapter 4 Configuration Installation and Operation Manual
4-28 Configuring Egate-100 for Operation Egate-100 Ver. 4.0
Egate-100
…Configuration> System> Clock Source> Master Clock
1. Source > (Rx Clock)
2. Wait to Restore (sec) ... (300)
3. Port Number [1 - 3] > (1)
Please select item <1 to 2>
ESC-prev.menu; !-main menu; &-exit
Figure
4-25. Master Clock Menu (SDH/SONET)
Egate-100
…Configuration> System> Clock Source> Master Clock
1. Source > (Rx Clock)
2. Wait to Restore(sec)[0 - 720] ... (300)
3. Port Number [1 - 3] ... (2)
>
Please select item <1 to 3>
S - Save
ESC-prev.menu; !-main menu; &-exit
Figure
4-26. Master Clock Menu (T3)
3. Choose one of the following to indicate the first-priority source of timing for
the Egate-100:
Rx Clock. If you want the master clock source to be the Rx clock from the
T3 active link. This is the default value
Internal. If you want the master clock to be the internal clock of the
Egate-100 unit.
4. If you choose Rx Clock, enter a Wait to Restore value: the number of seconds
(between 0 and 720) to wait before an attempt for the Master clock to be
restored.
5. For Rx Clock, specify the port number to be used.
6. Select Save.
7. From the Clock Source menu, select Fallback Clock.
The Fallback Clock menu appears as illustrated in
Figure
4-27
.
Egate-100
Main Menu> Configuration> System> Clock Source> Fallback Clock
1. Source > (Internal)
Please select item <1 to 2>
ESC-prev.menu; !-main menu; &-exit
Figure
4-27. Fallback Clock Menu (SDH/SONET)