Rockwell Automation Publication 750-TD001H-EN-P - June 2013 7
PowerFlex 750-Series AC Drives
Environmental Specifications
Category Specification
Altitude:
Based on Load:
Based on Voltage:
See Derating Guidelines on pages 14
…34.
Altitude Limit Above Sea Level
(2)(5)
System & Ground Configuration Overvoltage Category
(1)
400/480V AC 600V AC 690V AC
Center Grounded (Y Neutral) II (2) 9000 m
(3)
7500 m
(3)
7500 m
(3)
w/Solid Ground III (3) 4800 m 4800 m 4800 m
Ungrounded, Impedance
(4)
II (2) 4800 m 7500 m
(3)
4800 m
Grounded, or Corner Grounded
(4)
III (3) 2000 m 4800 m 2000 m
Notes: Based on EN61800-5-1 (Electro-thermal Safety Standard for drives)
(1) Overvoltage Categories:
Category II (Isolation Transformer Level) - Typically two levels of isolation or protection from outdoor power lines.
Category III (Most Common) Distribution Level Inside a Building - Typically one level of isolation or protection from outdoor power lines.
(2) Excluding failure from cosmic radiation. Cosmic radiation will increase rate of IGBT malfunction at altitudes greater than 3000 m above sea
level. Concrete walls and ceilings or concrete walls and large bottles of water overhead are examples of ways to shield against cosmic
radiation.
(3) Drive is limited to a maximum of 4800 m thermally. Refer to the Ambient Temperature/Load Derating Guidelines starting on page 14
.
(4) In CE installations, Frame 1 does not support ungrounded or corner grounded configurations.
(5) Frame 1 drives are limited to a maximum of 2000 m thermally. Refer to the Derating Guidelines starting on page 14
.
Maximum Surrounding Air Temperature
IP20, NEMA/UL Open Type:
IP00, NEMA/UL Open Type:
IP20, NEMA/UL Type 1 (w/Hood):
IP20, NEMA/UL Type 1 (w/Label):
IP20, NEMA/UL Type 1 (MCC Cabinet):
IP54, NEMA 12 (MCC Cabinet):
Flange Mount –
Front:
IP20, NEMA/UL Open Type:
IP00, NEMA/UL Open Type:
Back/Heat Sink:
IP66, NEMA/UL Type 4X
Stand-alone/Wall Mount –
IP54, NEMA/UL Type 12
0…50 °C (32…122 °F)
0…50 °C (32…122 °F)
0…40 °C (32…104 °F)
0…40 °C (32…104 °F)
0…40 °C (32…104 °F)
0…40 °C (32…104 °F)
0…50 °C (32…122 °F)
0…50 °C (32…122 °F)
0…40 °C (32…104 °F)
0…40 °C (32…104 °F)
Frames 1…5, All Ratings
Frames 6…7, All Ratings
Frames 1…5, All Ratings
Frames 6…7, All Ratings
Frames 8…10, All Ratings
Frames 8…10, All Ratings
Frames 2…5, All Ratings
Frames 6…7, All Ratings
Frames 2…7, All Ratings
Frames 2…7, All Ratings
Storage Temperature (all const.): -40…70 °C (-40…158 °F)
Atmosphere: Important: Drive must
not be installed in an area where the ambient atmosphere contains volatile or corrosive gas, vapors or
dust. If the drive is not going to be installed for a period of time, it must be stored in an area where it will not be exposed to a
corrosive atmosphere.
UV Radiation The HIM and IP54, NEMA/UL Type 12 drive plastics are not UV rated.
Relative Humidity: 5…95% non-condensing
Shock - Operating
Shock - Packaged for Shipment
Frames 1…6:
Frame 7:
Frames 8…10:
Frames 1…2:
Frames 3…4:
Frame 5:
Frames 6…10:
15 g peak for 11 ms duration (±1.0 ms)
10 g peak for 11 ms duration (±1.0 ms)
Power Core - 10 g peak for 11 ms duration (±1.0 ms)
in Cabinet w/Option Bay - 5 g peak for 11 ms duration (±1.0 ms)
381 mm (15 in.) drop height
330 mm (13 in.) drop height
305 mm (12 in.) drop height
Meets International Safe Transit Association (ISTA) test procedure 2B
Komentarze do niniejszej Instrukcji