g
Filtering and CM Cap Conguration ♦
Code Filtering Default CM Cap Connection
A Yes Jumper Removed
J Yes Jumper Installed
♦ 480V drives must select code "A." Jumpers are included for eld
reconguration as
desired.
h
Dynamic Braking &
Code Internal Resistor ♠ Internal Transistor ∇
A No Yes
NNo No
♠ Frames 1…2 only.
∇ Standard on Frames 1…5, optional on 6…7.
& Not available on Frames 8…10, specify Code "N."
PowerFlex 755 w/Options (21G) - Required Selections
Code Option Frames Type
LD Light Duty
8…10
System Overload
Duty Cycle
ND Normal Duty
HD Heavy Duty
P3
Input Thermal Magnetic
Circuit Breaker
8…10
Power
Disconnect
P5
Input Non-Fused Molded
Case Disconnect Switch
8 Only
8 Only
8 Only
8 Only
P14 Wiring Only Bay 8…10 Wiring Only Bay
Only one option of this type may be selected.
PowerFlex 755 w/Options (21G) - Additional Selections
Code Option Frames Type
P11 Input Contactor
Contactors
§
P12 Output Contactor
L1 3% Input Reactor
8…9
Reactors
L2 3% Output Reactor
L3 5% Input Reactor
L4 5% Output Reactor
P20 1200 Amp Bus
8…10
MCC Power Bus
Capacity
P22 2000 Amp Bus
P24 3000 Amp Bus
P30
UPS Control Bus, DC Input
w/Precharge only
8…10 UPS Control Bus
X1
Auxiliary Transformer
(500VA available), IP20
Cabinet Only
Auxiliary Power
Only one option of this type may be selected.
§ Contactor options are not available for systems with MCC power bus.
f3
ND Rating
600V, 60 Hz Input
Code Amps Hp
Frame
Enclosure Code
B, J,
L, T
FGN
K, P,
W, Y
R
1P7 1.7 1
–
333
–
–
2P7 2.7 2
3P9 3.9 3
6P1 6.1 5
9P0 9 7.5
011 11 10
012 12 10 – 6 6
017 17 15 3 3 3
018 18 15 – 6 6
022 22 20 3 3 3
023 23 20
–66
024 24 20
027 27 25 4 4 4
028 28 25 – 6 6
032 32 30 4 4 4
033 33 30 – 6 6
041 41 40 5 5 5
042 42 40 – 6 6
052 52 50 5 – 5
053 53 50
–
66
063 63 60
077 77 75
099 99 100
125 125 125
144 144 150
192 192 200
77
242 242 250
289 289 300
295 295 300
8
––
8 Δ
355 355 350
395 395 400
435 435 450
460 460 500
510 510 500
595 595 600
99Δ
630 630 700
760 760 800
825 825 900
900 900 950
980 980 1000
1K1 1110 1100
10
10
Δ
1K4 1430 1400
Δ Available as a drive with options (21G).
f4
ND Rating
690V, 50 Hz Input (not UL listed)
Code Amps kW
Frame
Enclosure Code
B, J,
L, T
FGN
K, P,
W, Y
R
012 12 7.5
–
–
66
–
–
015 15 11
020 20 15
023 23 18.5
030 30 22
034 34 30
046 46 37
050 50 45
061 61 55
082 82 75
098 98 90
119 119 110
142 142 132
171 171 160
77
212 212 200
263 263 250
265 265 250
8
––
8 Δ
330 330 315
370 370 355
415 415 400
460 460 450
500 500 500
590 590 560
99Δ
650 650 630
710 710 710
765 765 750
795 795 800
960 960 900
1K0 1040 1000
10
10
Δ
1K4 1400 1400
Δ Available as a drive with options (21G).
i
Door Mounted HIM (Frames 8…10)
Code Operator Interface
0 No Door Mounted HIM
2 Enhanced LCD, Full Numeric, IP20
4 Enhanced LCD, Full Numeric, IP66 NEMA Type 4X/12