Data Sheet
Uplink Interfaces
Pluggable SFP units provide the uplink
interfaces. A wide variety of optical
interfaces are available for ordering as
single, dual, or quad modules (see
Table 2
and
Ordering Options
).
It is strongly recommended to order this
device with original RAD SFPs installed.
This will ensure that prior to shipping,
RAD has performed comprehensive
functional quality tests on the entire
assembled unit, including the SFP
devices. RAD cannot guarantee full
compliance to product specifications for
units using non-RAD SFPs.
Redundancy
For transmission reliability, an optional
modular second link provides automatic
backup upon link failure. LRS-102 provides
power redundancy for nonstop operation.
Diagnostics
OP-108C and OP-106C feature
comprehensive test and diagnostics
capabilities that include local and remote
loopbacks on the uplink interface and on
each E1/T1 tributary link.
To facilitate system diagnostics, the card
versions feature LED status indicators
and AIS alarm generation and
recognition.
Fi
ure 2. Cor
orate Service Sharin
Management
Setup, control, and diagnostics are
performed by the LRS-102
management rack. The same
management options are available as
for the standalone versions.
Physical
Each card fits in a single slot of the
LRS-102 chassis.
Note: For OP-108C/OP-106C cards operating
in the Megaplex-4100 enclosure, refer to a
separate OP-108C/OP-106C data sheet
included into the Megaplex-4100 folder.
Power
The power for cards is provided by
the LRS-102 power supply.
Specifications
FIBER OPTIC INTERFACES
Optimux-108/Optimux-106: See
Table 1
OP-108C/OP-106C: See
Table 2
TRIBUTARY INTERFACES
Number of E1/T1 Channels
Standalone: 4
Card: 2 x 4 E1/T1 channels
Data Rate
E1: 2048 kbps
T1: 1544 kbps
Line Code
E1: HDB3
T1: B8ZS
Impedance
120Ω, E1 balanced
100Ω, T1 balanced
75Ω, E1 unbalanced
Connectors
Optimux-108
E1 balanced: RJ-45
E1 unbalanced: a pair of BNC
Optimux-106
RJ-45
OP-108C
E1 balanced: DB-44 connector on the
front module panel convertible to
80 balanced interfaces via adaptor cables
(see
Ordering Options
)
E1 unbalanced:
• DB-44 connector on the front module
panel convertible to 80 unbalanced
interfaces via adaptor cables (see
Ordering Options
)
• A pair of BNC connectors for each E1
port on a special LRS-102 rack version
OP-106C
DB-44 connector on the front module
panel convertible to 80 balanced T1
interfaces via adaptor cables (see
Ordering Options
)
MNG–ETH INTERFACE (STANDALONE
ONLY)
Type
10/100BaseT
Connector
Shielded RJ-45
Order from: Cutter Networks
Ph: 727-398-5252 / Fx: 727-397-9610
Komentarze do niniejszej Instrukcji