RAD Data comm FCD-V35 Dokumentacja Strona 17: Configuration Procedure

/ 228
Spis treści
Rozwiązywanie problemów
Installation and Operation Manual
Quick Start Guide
FCD-E1LC Ver. 1.0
Configuration Using a Supervisory Terminal
3

Configuration Procedure

Perform the following actions in the order given below.
Step
Action
Use the Command
1
Reset the database to the default parameters
INIT DB
2
Define the terminal control codes
DEF TERM
3
Configure the supervisory port
DEF SP
DEF CALL
4
Set FCD-E1LC system time and date
TIME
DATE
5
Configure management access and system parameters
DEF SYS
DEF AGENT
DEF MANAGER LIST
DEF ROUTE
6
Configure the main link parameters
DEF ML
7
Configure the sub link parameters (optional)
DEF SL
8
Configure the data channel parameters
DEF CH 1
DEF CH 2
(when installed)
9
Configure system timing
DEF SYS
10
Define the general system parameters
DEF NAME
DEF NODE
DEF PWD
11
Define the alarm handling parameters
DEF AR
DEF ALM MASK
FCD-E1LC is now ready for operation.