RAD Data comm FCD-V35 Dokumentacja Strona 100: FCD-E1LC Ver. 1.0

/ 228
Spis treści
Rozwiązywanie problemów
Chapter 6 Troubleshooting and Diagnostics
Installation and Operation Manual
6-8
Handling Alarms
FCD-E1LC Ver. 1.0
Table 6-2. FCD-E1LC Alarm Messages (Cont.)
Alarm
Number
Terminal Message
Description
Corrective Actions
Severity
Type
23
AIS OCCURRED
AIS is being detected on the link
Problem at the equipment connected to the remote end of
the link
MAJOR
ON/OFF
24
AIS SYNC LOSS
Local loss of frame synchronization
alarm on the main link, caused by AIS
condition
Problem at the equipment connected to the remote end of
the link
MAJOR
ON/OFF
25
LOCAL SYNC LOSS
Local loss of frame synchronization
alarm on the main link
1.
Check cable connections to the link connector.
2.
Check line and/or other communication equipment
providing the link to the remote FCD-E1LC
3.
Replace the FCD-E1LC
MAJOR
ON/OFF
26
LOCAL MF ALARM
Local loss of multiframe
synchronization alarm on the main link
1.
Check that the correct framing mode is used at the
local and remote ends.
2.
Perform the corrective actions listed for LOCAL SYNC
LOSS.
MAJOR
ON/OFF
27
REMOTE MF ALARM
Remote loss of multiframe
synchronization alarm on the main link
Problem at the remote equipment.
MAJOR
ON/OFF
28
REMOTE SYNC LOSS
Remote loss of frame synchronization
alarm on the main link
Problem at the remote equipment. Perform the following
checks on the remote equipment:
1.
Check cable connections to the link connector.
2.
Check line and/or other communication equipment
providing the link to the remote equipment.
3.
Replace the equipment.
MAJOR
ON/OFF
29
FRAME SLIP
Frame slips are detected on the main
link. Updated once per second.
Note:This alarm message is not
displayed during local loss of frame
synchronization
1.
Incorrect selection of master clock source
2.
Problem at far end (unstable clock source)
3.
Replace the FCD-E1LC only if steps 1 and 2 do not
correct the problem.
MAJOR
ON

Plik PDF · ·

Drukuj