Module Installation and Operation MP-2100 HS-R
Installation and Operation Manual
2-2 Preparation for Installation
2.2 Preparation for Installation
The HS-R modules have two jumpers that control the connection of the frame
ground to pin 1 in the channel connectors.
Default setting: pins connected to frame ground.
Figure 2-1 shows the location of the two jumpers for the HS-R. Note that the
modules include additional factory-set jumpers that must not be changed by the
user.
Jumper J3
NC
Frame Ground not
Connected to Pin 1
of CH.1-2 Connector
FGND
Frame Ground
Connected to Pin 1
of CH.1-2 Connector
Jumper J4
NC
Frame Ground not
Connected to Pin 1
of CH.3-4 Connector
FGND
Frame Ground
Connected to Pin 1
of CH.3-4 Connector
J1
FGND
J3
FGND SEL 1
NC
FGND
J4
FGND SEL 2
NC
Figure 2-1 HS-R Internal Settings
Module Installation
Refer to the system installation plan and insert the module in the assigned I/O slot
of the Megaplex enclosure. The module starts operating as soon as it is plugged
into an operating enclosure.