Chapter 3 Configuration Management User’s Manual
3-12 Configuring Operational Parameters Optimux-34 Ver. 2.81
Figure 3-8. E1 Channel Parameters Dialog Box
3. Fill in the fields, as described in
Table 3-5
.
4. Click <Set> to implement the changes.
If the User-ETH port has been configured to a rate > 0, the corresponding E1
ports fields will be all Read-Only, and the <Set> button will be disabled.
Table 3-5. E1 Port Parameters
Parameter Possible Values / Remarks
Administrative Status Up
Down
Read-Write (Read-Only, see
Note
above)
Port Type E1
Read-Only
User Name The name for the interface as specified by the network manager.
String of up to 15 characters
Read-Write
Connector Type RJ-45
Read-Only
Interface Type Unbalanced: 75Ω
Balanced: 120Ω
Read-Write