MiTOP-E1/T1 Ver. 1.0 Introduction 5-1
Chapter 5
Configuring a Typical
Application
This chapter provides detailed instructions for setting up a typical application
using a MiTOP-E1/T1 unit.
Configuration values shown in this chapter are examples only.
5.1 Introduction
This chapter explains how to configure a typical pseudowire application, using
MiTOP-E1/T1 delivering a full E1 stream to a central Gmux-2000 with GbE and
E1-PW/28 modules. MiTOP-E1/T1 is installed in the Fast Ethernet port of the
ETX-550 aggregator.
Figure
5-1. Typical Pseudowire Application
The order of the configuration steps detailed below is optional. You can configure
the three devices used in the sample application in any suitable order.
1. Configuring MiTOP-E1/T1:
a. Setting host IP parameters
b. Configuring E1 at the physical level
c. Defining the pseudowire peer
d. Configuring the general and service parameters of the pseudowire
connection.