Installation & Operation Manual System Installation
3/11/98 12:29 Replacing The Ventilation Fan 3-15
High Power
Module
1. Remove the four screws holding the power supply to the hub
enclosure. The screws are marked 1 through 4 on the illustration
below.
2. Remove the four screws, marked a through d, that attach the fan to the
faceplate.
Figure 3-5 Fan Screw Location in High Power Module
3. Disconnect the connector terminating the fan wires from the hub.
4. Cut the fan wires approximately at mid-length and discard the fan.
CONNECTOR
WIRES TO BE CUT
(RED AND BLACK
FROM THE FAN)
Figure 3-6 Connector Wires to be Cut