Installation and Operation Manual Chapter 4 Configuration
MiRICi-E3T3 Ver. 2.2 Configuring for Operation 4-9
Remote defect indication (RDI)
Alarm indication signal (AIS)
³ To configure the LOS behavior:
1. In the System menu (Configuration > System), click LOS Behavior.
The LOS Behavior menu appears, allowing you to enable or disable the
LOS behavior, depending on its cause.
MiRICi-E3T3
Configuration > System > LOS Behavior
LOS caused by:
LOS Disable
RLOL Disable
RDI Disable
AIS Disable
Figure
4-9. LOS Behavior Screen
2. Specify MiRICi-E3T3’s LOS behavior.
LOS:
Enable (LOS on the TDM link is propagated to the Ethernet interface)
Disable (LOS on the TDM link is not propagated to the Ethernet
interface)
RLOL:
Enable (RLOL on the TDM link is propagated to the Ethernet interface)
Disable (RLOL on the TDM link is not propagated to the Ethernet
interface)
RDI:
Enable (RDI on the TDM link is propagated to the Ethernet interface)
Disable (RDI on the TDM link is not propagated to the Ethernet
interface)
AIS:
Enable (AIS on the TDM link is propagated to the Ethernet interface)
Disable (AIS on the TDM link is not propagated to the Ethernet
interface)