Installation and Operation Manual
FOM-
4
0
High-Speed Fiber Optic
M
odem
Version 2
Przeglądanie stron 0
1 2 3 4 5 6 ... 73 74

Podsumowanie treści

Strona 1 - High-Speed Fiber Optic

Installation and Operation Manual FOM-40 High-Speed Fiber Optic Modem Version 2

Strona 2

Declaration of Conformity Manufacturer's Name: RAD Data Communications Ltd. Manufacturer's Address: 24 Raoul Wallenberg St. Tel Aviv 6

Strona 3 - High-Speed Fiber Optic Modem

Installing FOM-40 1 Quick Start Guide Installation of FOM-40 should be carried out only by an experienced technician. If you are familiar with FOM

Strona 4 - Limited Warranty

Quick Start Guide FOM-40 Installation and Operation Manual 2 Installing FOM-40 Switch Description Values Default Setting 6 7 6 7 INT – Interna

Strona 5 - General Safety Instructions

FOM-40 Installation and Operation Manual Quick Start Guide Installing FOM-40 3 Switch Description Values Default Setting Baud Rate [kbps] 1 2

Strona 6 - Handling Energized Products

Quick Start Guide FOM-40 Installation and Operation Manual 4 Operating FOM-40 2. Operating FOM-40 FOM-40 does not require operator attention once i

Strona 7

04-Jul-2005 11:00 FOM-40 Installation and Operation Manual i Contents Chapter 1. Introduction 1.1 Overview...

Strona 8 - FCC-15 User Information

Table of Contents ii FOM-40 Installation and Operation Manual Line Connector...

Strona 9 - Warning

Overview 1-1 Chapter 1 Introduction 1.1 Overview FOM-40 is a synchronous high-speed fiber optic modem that provides a secure, long-range data link b

Strona 10 - Declaration of Conformity

Chapter 1 Introduction FOM-40 Installation and Operation Manual 1-2 Overview Figure 1-2 shows a application of FOM-40 that uses an X.21 interface

Strona 11 - Quick Start Guide

FOM-40 Installation and Operation Manual Chapter 1 Introduction Physical Description 1-3 Diagnostics FOM-40 features RLB and LLB diagnostics for

Strona 13 - Connecting the Cables

Chapter 1 Introduction FOM-40 Installation and Operation Manual 1-4 Functional Description 1.3 Functional Description This section contains functi

Strona 14 - 2. Operating FOM-40

FOM-40 Installation and Operation Manual Chapter 1 Introduction Technical Specifications 1-5 The test can be carried out in local analog loopback

Strona 15 - Contents

Chapter 1 Introduction FOM-40 Installation and Operation Manual 1-6 Technical Specifications ERR (red) Error Physical FOM-40/SA Height 40 mm

Strona 16 - Table of Contents

Site Requirements and Prerequisites 2-1 Chapter 2 Installation and Setup This chapter describes installation and setup procedures for the standalone

Strona 17 - Chapter 1

Chapter 2 Installation and Setup FOM-40 Installation and Operation Manual 2-2 Installing FOM-40 2.2 Package Contents The FOM-40 package includes t

Strona 18 - Features

FOM-40 Installation and Operation Manual Chapter 2 Installation and Setup Installing FOM-40 2-3 Connecting the Cables Figure 2-1. FOM-40 Rear

Strona 19 - 1.2 Physical Description

Chapter 2 Installation and Setup FOM-40 Installation and Operation Manual 2-4 Installing FOM-40 Connecting the Power To connect FOM-40 to the powe

Strona 20 - 1.3 Functional Description

Front Panel Controls and Indicators 3-1 Chapter 3 Operation This chapter provides the following information for the FOM-40 standalone modem: • FOM

Strona 21 - 1.4 Technical Specifications

Chapter 3 Operation FOM-40 Installation and Operation Manual 3-2 Turning On FOM-40 Table 3-1. FOM-40 Front Panel Controls and Indicators Name Ty

Strona 22

FOM-40 Installation and Operation Manual Chapter 3 Operation Turning Off FOM-40 3-3 3.3 Normal Indications Table 3-2 shows the correct status of

Strona 23 - Installation and Setup

FOM-40 Version 2 High-Speed Fiber Optic Modem Installation and Operation Manual Notice This manual contains information that is proprietary to RA

Strona 24 - 2.3 Installing FOM-40

Chapter 3 Operation FOM-40 Installation and Operation Manual 3-4 Turning Off FOM-40

Strona 25

Configuring FOM-40 4-1 Chapter 4 Configuration This chapter contains the following information for the FOM-40 standalone modem: • Configuration pro

Strona 26 - Connecting the Power

Chapter 4 Configuration FOM-40 Installation and Operation Manual 4-2 FOM-40 Dip Switches 4.2 FOM-40 Dip Switches The following FOM-40 rear panel

Strona 27 - Operation

FOM-40 Installation and Operation Manual Chapter 4 Configuration FOM-40 Dip Switches 4-3 Table 4-1. FOM-40 DIP Switches Settings Switch Descrip

Strona 28 - 3.2 Turning On FOM-40

Chapter 4 Configuration FOM-40 Installation and Operation Manual 4-4 FOM-40 Dip Switches Table 4-1. FOM-40 Dip Switches Settings (Cont.) Switch

Strona 29 - 3.4 Turning Off FOM-40

Loopback Tests 5-1 Chapter 5 Troubleshooting and Diagnostics This chapter contains procedures for performing FOM-40 diagnostic tests. Use the test

Strona 30 - 3-4 Turning Off FOM-40

Chapter 5 Troubleshooting and Diagnostics FOM-40 Installation and Operation Manual 5-2 Loopback Tests Local Analog Loopback (LLB) The local analog

Strona 31 - Configuration

FOM-40 Installation and Operation Manual Chapter 5 Troubleshooting and Diagnostics Loopback Tests 5-3 Remote Digital Loopback (RLB) The remote di

Strona 32 - 4.2 FOM-40 Dip Switches

Chapter 5 Troubleshooting and Diagnostics FOM-40 Installation and Operation Manual 5-4 Internal BERT Local Digital Loopback (DIG) The local digita

Strona 33 - FOM-40 Dip Switches 4-3

FOM-40 Installation and Operation Manual Chapter 5 Troubleshooting and Diagnostics Internal BERT 5-5 Modem Self-Test The modem self-test checks t

Strona 34 - 4-4 FOM-40 Dip Switches

Limited Warranty RAD warrants to DISTRIBUTOR that the hardware in the FOM-40 to be delivered hereunder shall be free of defects in material and wor

Strona 35 - Diagnostics

Chapter 5 Troubleshooting and Diagnostics FOM-40 Installation and Operation Manual 5-6 Inverting Signal for V.54 Compatibility ERRERRPattern Gene

Strona 36 - Local Analog Loopback (LLB)

FOM-40 Installation and Operation Manual Chapter 5 Troubleshooting and Diagnostics Technical Support 5-7 Figure 5-6. Switch SW6/1 Inverts Signa

Strona 37 - Loopback Tests 5-3

Chapter 5 Troubleshooting and Diagnostics FOM-40 Installation and Operation Manual 5-8 Technical Support

Strona 38 - 5.2 Internal BERT

ASM-MN-214 Card Cage 6-1 Chapter 6 FOM-40/R Card This chapter describes the FOM-40/R card, designed for installation in the ASM-MN-214 card cage. T

Strona 39 - Two-BER Test

Chapter 6 FOM-40/R Card FOM-40 Installation and Operation Manual 6-2 ASM-MN-214 Card Cage Term i n a lBlockCIA/V.35/1CIA/X.21/1CBL- 530/449Term i

Strona 40 - FOM-40 FOM-40

FOM-40 Installation and Operation Manual Chapter 6 FOM-40/R Card Power Supply 6-3 6.2 Power Supply Power is supplied to the FOM-40/R card from th

Strona 41 - 5.4 Technical Support

Chapter 6 FOM-40/R Card FOM-40 Installation and Operation Manual 6-4 FOM-40/R Front Panel 6.3 FOM-40/R Front Panel Figure 6-2 shows the FOM-40/R

Strona 42 - 5-8 Technical Support

FOM-40 Installation and Operation Manual Chapter 6 FOM-40/R Card FOM-40/R Front Panel 6-5 Figure 6-3. ASM-MN-214 Front Panel

Strona 43 - FOM-40/R Card

Chapter 6 FOM-40/R Card FOM-40 Installation and Operation Manual 6-6 Installing the FOM-40/R Card 6.4 Installing the FOM-40/R Card Setting Inter

Strona 44 - 6-2 ASM-MN-214 Card Cage

FOM-40 Installation and Operation Manual Chapter 6 FOM-40/R Card Installing the FOM-40/R Card 6-7 Table 6-1. FOM-40/R Internal Jumpers and Switc

Strona 45 - 6.2 Power Supply

General Safety Instructions The following instructions serve as a general guide for the safe installation and operation of telecommunications produc

Strona 46 - 6.3 FOM-40/R Front Panel

Chapter 6 FOM-40/R Card FOM-40 Installation and Operation Manual 6-8 Installing the FOM-40/R Card Installing FOM-40/R into the ASM-MN-214 Card Ca

Strona 47 - FOM-40/R Front Panel 6-5

V.24, V.35 and X.21 Interface Connectors A-1 Appendix A Connector Wiring A.1 V.24, V.35 and X.21 Interface Connectors Table A-1 describes the sign

Strona 48

Appendix A Connector Wiring FOM-40 Installation and Operation Manual A-2 V.24, V.35 and X.21 Interface Connectors Table A-1. DTE Interface Signa

Strona 49

FOM-40 Installation and Operation Manual Appendix A Connector Wiring RS-530 and V.36 Interface Connectors A-3 A.2 RS-530 and V.36 Interface Conn

Strona 50 - Connecting the Interfaces

Appendix A Connector Wiring FOM-40 Installation and Operation Manual A-4 FOM-40/R with Ethernet Interface, DTE Connection A.3 T1 Interface Conne

Strona 51 - Connector Wiring

FOM-40 Installation and Operation Manual Appendix A Connector Wiring FOM-40/R with G.703 Codirectional Interface, DTE Connection A-5 A.5 FOM-40/

Strona 52

Appendix A Connector Wiring FOM-40 Installation and Operation Manual A-6 FOM-40/R with G.703 Codirectional Interface, DTE Connection

Strona 53 - 20 RC

Introduction B-1 Appendix B IR-ETH/QV Interface Module B.1 Introduction The IR-ETH/QV interface module replaces the IR-ETH/QN interface module. The

Strona 54 - A.3 T1 Interface Connector

Appendix B IR-ETH/QV Interface Module FOM-40 Installation and Operation Manual B-2 IR-ETH/QV Options B.2 IR-ETH/QV Options Standalone FOM-40 Figur

Strona 55 - Connection

FOM-40 Installation and Operation Manual Appendix B IR-ETH/QV Interface Module Technical Specifications B-3 B.3 Technical Specifications Bridge L

Strona 56

Handling Energized Products General Safety Practices Do not touch or tamper with the power supply when the power cord is connected. Line voltages

Strona 57 - B.1 Introduction

Appendix B IR-ETH/QV Interface Module FOM-40 Installation and Operation Manual B-4 Installation and Operation B.4 Installation and Operation Figu

Strona 58 - B.2 IR-ETH/QV Options

FOM-40 Installation and Operation Manual Appendix B IR-ETH/QV Interface Module Installation and Operation B-5 Table B-2. DIP SW1 Switch Settings

Strona 59 - B.3 Technical Specifications

Appendix B IR-ETH/QV Interface Module FOM-40 Installation and Operation Manual B-6 Installation and Operation Backpressure and Flow Control DIP s

Strona 60 - Setting the DIP Switches

Introduction C-1 Appendix C IR-G.703/CO Interface Module C.1 Introduction IR-G.703/CO is an interface module for RAD modems that converts G.703 64 k

Strona 61

Appendix C IR-G.703/CO Interface Module FOM-40 Installation and Operation Manual C-2 Selecting the IR-G.703/CO Timing C.2 Selecting the IR-G.703

Strona 62 - Connecting the LAN

FOM-40 Installation and Operation Manual Appendix C IR-G.703/CO Interface Module Selecting the IR-G.703/CO Timing C-3 INT/RCV Timing The INT/RCV

Strona 63 - IR-G.703/CO Interface

Appendix C IR-G.703/CO Interface Module FOM-40 Installation and Operation Manual C-4 Selecting the IR-G.703/CO Timing

Strona 64 - EXT Timing

Introduction D-1 Appendix D IR-X.21Interface Module D.1 Introduction IR-X.21 is an interface module that converts X.21 signals to TTL levels. The co

Strona 65 - INT/RCV Timing

Appendix D IR-X.21Interface Module FOM-40 Installation and Operation Manual D-2 Selecting the IR-X.21 Timing Table D-1. IR-X.21 Connector Pin As

Strona 66

24 Raoul Wallenberg St., Tel Aviv 69719, IsraelTel: +972-3-6458181, Fax: +972-3-6483331, +972-3-6498250E-mail: , Web site:

Strona 67 - D.1 Introduction

Connection of Data and Telecommunications Cables Data and telecommunication interfaces are classified according to their safety status. The followin

Strona 69 - Customer Response Form

Error Report Type of Error(s) ❒ Incompatibility with product or Problem(s): ❒ Difficulty in understanding text ❒ Regulatory information

Strona 72

Publication No. 281-200-07/05 www.rad.com INTERNATIONAL HEADQUARTERS: 24 Raoul Wallenberg Street, Tel Aviv 69719, Israel, Tel: 972-3-6458181 Fax: 972

Strona 73

To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cords. Pour réduire les risques s’incendie, utiliser seulement

Strona 74

Canadian Emission Requirements This Class A digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment Regulation.

Komentarze do niniejszej Instrukcji

Brak uwag