Rad-data-comm ASMI-450 Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Sprzęt komputerowy Rad-data-comm ASMI-450. RAD Data comm ASMI-450 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 117
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
ASMi-450
High-Speed HDSL Modem
Installation and Operation Manual
Notice
This manual contains information that is proprietary to RAD Data Communications. No part of this
publication may be reproduced in any form whatsoever without prior written approval by RAD Data
Communications.
No representation or warranties for fitness for any purpose other than what is specifically mentioned in this
manual is made either by RAD Data Communications or its agents.
For further information contact RAD Data Communications at the address below or contact your local
distributor.
RAD data communications
Headquarters
12 Hanechoshet Street
Tel Aviv 69710 Israel
Tel: 972-3-6458181
Fax: 972-3-6498250
RAD data communications
US East
900 Corporate Drive
Mahwah, NJ 07430 USA
Tel: (201) 529-1100
Fax: (201) 529-5777
RAD data communications
US West
7711 Center Avenue #350
Huntington Beach, CA 92647 USA
Tel: (714) 897-2448
Fax: (714) 891-1764
© 1997 RAD Data Communications Ltd. Publication No. 634-200-11/97
Przeglądanie stron 0
1 2 3 4 5 6 ... 116 117

Podsumowanie treści

Strona 1 - ASMi-450

ASMi-450High-Speed HDSL ModemInstallation and Operation ManualNoticeThis manual contains information that is proprietary to RAD Data Communications. N

Strona 2 - Warranty

Contentsx ASMi-450 Installation and Operation Manual

Strona 3 - Telecommunication Safety

Connector WiringA-2 ASMi-450 Installation and Operation ManualTable A-2. V.36/RS-449/422 DCE Interface Adapter CablePin Designation Direction Function

Strona 4 - Regulatory Information

Connector WiringASMi-450 Installation and Operation Manual A-3A.2 V.35 DCE ConnectorWhen the ASMi-450 is ordered with an V.35 DCE interface, the phys

Strona 5 - Declaration of Conformity

Connector WiringA-4 ASMi-450 Installation and Operation ManualA.3 X.21 DCE ConnectorWhen the ASMi-450 is ordered with an X.21 interface, the physical

Strona 6

Connector WiringASMi-450 Installation and Operation Manual A-5A.4 HDSL Line ConnectorThe HDSL line is terminated in an eight-pin RJ-45 connector, des

Strona 7

Connector WiringA-6 ASMi-450 Installation and Operation ManualA.6 Ethernet Interface ConnectorWhen the ASMi-450 is ordered with an Ethernet interface

Strona 8

ASMi-450 Installation and Operation Manual B-1Appendix BSNMP ManagementB.1 ScopeThis Appendix provides the specific information required for the manag

Strona 9

SNMP ManagementB-2 ASMi-450 Installation and Operation ManualB.2 SNMP EnvironmentGeneralThe SNMP management functions of the ASMi-450 are provided by

Strona 10 - Contents

SNMP ManagementASMi-450 Installation and Operation Manual B-3The Management Information BaseThe management information base (MIB) includes a collectio

Strona 11 - List of Figures

SNMP ManagementB-4 ASMi-450 Installation and Operation ManualIn addition, the ASMi-450 SNMP agent supports the RAD-private (enterprise-specific) MIB.•

Strona 12

SNMP ManagementASMi-450 Installation and Operation Manual B-5When an SNMP message is received by the addressed entity, first it checks theoriginator&a

Strona 13 - List of Tables

ASMi-450 Installation and Operation Manual xiList of FiguresFigure 1-A. Typical Application for ASMi-450 with Data Interface ...

Strona 14

SNMP ManagementB-6 ASMi-450 Installation and Operation ManualB.3 IP EnvironmentGeneralThe SNMP agent of the ASMi-450 communicates using the Serial Lin

Strona 15 - Quick-Start Guide

SNMP ManagementASMi-450 Installation and Operation Manual B-7• Host Portion. The host portion is used to identify an individual hostconnected to the

Strona 16 - 2. Configuration Procedure

SNMP ManagementB-8 ASMi-450 Installation and Operation ManualB.4 SNMP TrapsThe SNMP agent of the ASMi-450 supports the standard MIB-II traps. Inadditi

Strona 17 - 3. Command Index

ASMi-450 Installation and Operation Manual C-1Appendix CInstallation in 19" RacksC.1 GeneralThe ASMi-450 can be installed in 19" racks. Unit

Strona 18

Installation in 19" RacksC-2 ASMi-450 Installation and Operation ManualC.2 Installation of Single UnitThe rack adapter kit for single unit insta

Strona 19 - Introduction

Installation in 19" RacksASMi-450 Installation and Operation Manual C-3C.3 Installation of Two UnitsGeneralThe two-unit rack adapter kit include

Strona 20 - Ethernet Interface

Installation in 19" RacksC-4 ASMi-450 Installation and Operation Manual• Fasten one short adapter bracket to the left-hand side wall of the unit

Strona 21 - HDSL Subsystem

ASMi-450Installation Instructions forCompliance with EMC RequirementsTo comply with electromagnetic compatibility requirements,two ferrite cores shoul

Strona 22 - System Timing

List of Figuresxii ASMi-450 Installation and Operation Manual

Strona 23 - Operation

ASMi-450 Installation and Operation Manual xiiiList of TablesTable 3-A. ASMi-450 Controls, Connectors and Indicators ...

Strona 24

List of Tablesxiv ASMi-450 Installation and Operation Manual

Strona 25

ASMi-450 Installation and Operation Manual Quick-Start Guide - 1Quick-Start GuideIf you are familiar with HDSL transmission equipment, use this guide

Strona 26 - 1.2 Operating Environment

Quick-Start GuideQuick-Start Guide - 2 ASMi-450 Installation and Operation Manual2. Configuration ProcedureYou are ready to start ASMi-450 configurati

Strona 27 - System Functions

Quick-Start GuideASMi-450 Installation and Operation Manual Quick-Start Guide - 33. Command IndexDisplay the index of commands by typing the help comm

Strona 28 - 1.3 Technical Specifications

Quick-Start GuideQuick-Start Guide - 4 ASMi-450 Installation and Operation ManualNotes

Strona 29

ASMi-450 Installation and Operation Manual 1-1Chapter 1Introduction1.1 Functional DescriptionPurpose and MainFeaturesThe ASMi-450 is a high-speed HDSL

Strona 30

WarrantyThis RAD product is warranted against defects in material and workmanship for a period of one year fromdate of shipment. During the warranty p

Strona 31 - Installation

Introduction1-2 ASMi-450 Installation and Operation Manual• Ethernet 10BaseT interface. The interface can use unshielded and shieldedtwisted pair (UT

Strona 32 - 2.3 Site Requirements

IntroductionASMi-450 Installation and Operation Manual 1-3The interface includes a full-feature remote bridge, that operates at the physicaland data l

Strona 33 - Opening ASMi-450

Introduction1-4 ASMi-450 Installation and Operation Manual• The remote unit, located at the remote end of the link (customer side),serves as the netw

Strona 34 - Functions

IntroductionASMi-450 Installation and Operation Manual 1-5Figure 1-D. Flow of Timing Signals through ASMi-450 System in the Internal Timing Mode• ASM

Strona 35 - . ASMi-450 Internal Settings

Introduction1-6 ASMi-450 Installation and Operation ManualThe remote management functions are performed through a serial RS-232 portthat enables seria

Strona 36

IntroductionASMi-450 Installation and Operation Manual 1-7Test and Diagnostics CapabilitiesThe ASMi-450 has comprehensive diagnostics capabilities. AS

Strona 37 - ASMi-450 Cover

Introduction1-8 ASMi-450 Installation and Operation Manual1.2 Operating EnvironmentThis section describes the HDSL environment, with special emphasis

Strona 38 - 2.5 Connections

IntroductionASMi-450 Installation and Operation Manual 1-9By reducing the line symbol rate, the maximum range that can be reached isincreased. This is

Strona 39 - Connections

Introduction1-10 ASMi-450 Installation and Operation Manual1.3 Technical SpecificationsHDSL InterfaceSignal Format 2B1Q line codingLine Type One uncon

Strona 40 - Connection

IntroductionASMi-450 Installation and Operation Manual 1-11Ethernet InterfaceCompliance IEEE 802.3Interface Type 10BaseT for use on UTP and STP mediaI

Strona 41 - Instructions

Safety WarningsThe exclamation point within a triangle is intended to warn the operator or servicepersonnel of operation and maintenance factors relat

Strona 42

Introduction1-12 ASMi-450 Installation and Operation ManualWord Format− One start bit− 7 or 8 data bits− Parity: none, odd, or even− One stop bitConne

Strona 43 - Indicators

ASMi-450 Installation and Operation Manual 2-1Chapter 2Installation2.1 GeneralThe ASMi-450 is delivered completely assembled. It is designed for insta

Strona 44 - Display Functions

Installation2-2 ASMi-450 Installation and Operation Manual2.2 UnpackingA preliminary inspection of the equipment container should be made beforeunpack

Strona 45

InstallationASMi-450 Installation and Operation Manual 2-32.4 ASMi-450 Configuration InformationGeneralThis paragraph provides information on the fun

Strona 46 - Push-buttons

Installation2-4 ASMi-450 Installation and Operation ManualFigure 2-1. Identification of Cover ScrewsJumper and SwitchLocation andFunctionsThe ASMi-450

Strona 47

InstallationASMi-450 Installation and Operation Manual 2-5Figure 2-2. ASMi-450 Internal Settings

Strona 48 - Designation Function Values

Installation2-6 ASMi-450 Installation and Operation ManualDIP switch S1 allows the user to control the reloading of the desired group ofdefault parame

Strona 49

InstallationASMi-450 Installation and Operation Manual 2-7NoteUser-selected parameter values are not erased by setting one or more switchsections to O

Strona 50 - 3.6 Operating Instructions

Installation2-8 ASMi-450 Installation and Operation Manual2.5 ConnectionsConnectorLocationFigure 2-3 shows typical rear panels of ASMi-450 units, and

Strona 51 - Normal Indications

InstallationASMi-450 Installation and Operation Manual 2-9WarningBefore switching on this instrument and before connecting any other cable,the protect

Strona 52 - Turn-off

Regulatory InformationFCC-15 User InformationThis equipment has been tested and found to comply with the limits of the Class A digital device, pursuan

Strona 53 - Configuration

Installation2-10 ASMi-450 Installation and Operation Manualfirst the interface adapter cable to the RS-530connector, then connect the user's data

Strona 54 - Step Action Key Display

ASMi-450 Installation and Operation Manual 3-1Chapter 3Front-Panel OperatingInstructions3.1 ScopeIn this chapter you will find detailed instructions f

Strona 55 - Guidelines

Front-Panel Operating Instructions3-2 ASMi-450 Installation and Operation Manual3.2 Front Panel Controls, Connectors, and IndicatorsFigure 3-1 shows

Strona 56

Front-Panel Operating InstructionsASMi-450 Installation and Operation Manual 3-3Ethernet InterfaceIndicatorsFigure 3-2 shows the indicators located on

Strona 57

Front-Panel Operating Instructions3-4 ASMi-450 Installation and Operation Manual3.3 Control of ASMi-450 Operation, GeneralGeneralASMi-450 operating m

Strona 58

Front-Panel Operating InstructionsASMi-450 Installation and Operation Manual 3-5Status MessagesWhen the ASMi-450 is not being configured and no test i

Strona 59 - ASMi-450 Control

Front-Panel Operating Instructions3-6 ASMi-450 Installation and Operation ManualOrganization ofASMi-450 DisplayThe ASMi-450 display has two rows:• Up

Strona 60 - 4.2 Hardware Requirements

Front-Panel Operating InstructionsASMi-450 Installation and Operation Manual 3-7If you make an incorrect selection, the selection is not accepted. In

Strona 61

Front-Panel Operating Instructions3-8 ASMi-450 Installation and Operation Manual3.4 System Configuration ParametersTable 3-3 lists the available syst

Strona 62 - Function

Front-Panel Operating InstructionsASMi-450 Installation and Operation Manual 3-93.5 Control Port Configuration ParametersTable 3-4 lists the availabl

Strona 63 - Terminal

Declaration of ConformityManufacturer’s Name:RAD Data Communications Ltd.Manufacturer’s Address:12 Hanechoshet St.Tel Aviv 69710Israeldeclares that th

Strona 64 - Protocol

Front-Panel Operating Instructions3-10 ASMi-450 Installation and Operation Manual3.6 Operating InstructionsThis paragraph covers the following activit

Strona 65 - Commands

Front-Panel Operating InstructionsASMi-450 Installation and Operation Manual 3-11Step Action Key Display1 Bring the cursor under the top row (if notal

Strona 66 - Command Purpose Options

Front-Panel Operating Instructions3-12 ASMi-450 Installation and Operation ManualIn Table 5-1, you will find two types of alarms, designated as ON/OFF

Strona 67 - CLR ALM [/A]

Front-Panel Operating InstructionsASMi-450 Installation and Operation Manual 3-133.7 Local Configuration Set-Up ProcedureBefore starting any configur

Strona 68 - DEF AGENT

Front-Panel Operating Instructions3-14 ASMi-450 Installation and Operation ManualStep Action Key Display1 Bring the cursor under the top row (if notal

Strona 69 - DEF NAME

Front-Panel Operating InstructionsASMi-450 Installation and Operation Manual 3-15Step Action Key Display9 After completing the configuration actions,y

Strona 70 - DEF NODE

Front-Panel Operating Instructions3-16 ASMi-450 Installation and Operation ManualSP PARAMETERSSee parameter definitions in Section 3-5.SPEED_BPS Selec

Strona 71

Front-Panel Operating InstructionsASMi-450 Installation and Operation Manual 3-173.8 LCD Configuration Error MessagesThe ASMi-450 detects configurati

Strona 72

Front-Panel Operating Instructions3-18 ASMi-450 Installation and Operation ManualNotes

Strona 73

ASMi-450 Installation and Operation Manual 4-1Chapter 4ASMi-450 Controlfrom the Control Port4.1 GeneralThis Chapter provides detailed instructions for

Strona 75

ASMi-450 Control from the Control Port4-2 ASMi-450 Installation and Operation Manual4.2 Hardware RequirementsTerminalCharacteristicsAny standard ASCII

Strona 76

ASMi-450 Control from the Control PortASMi-450 Installation and Operation Manual 4-3Interface TypeControl Line DCE DTECTS Out Not usedDCD Out Out

Strona 77

ASMi-450 Control from the Control Port4-4 ASMi-450 Installation and Operation Manual• When the node address is 0, the DCD line is always ON (active).

Strona 78 - DSP ST PORT [Option]

ASMi-450 Control from the Control PortASMi-450 Installation and Operation Manual 4-54.3 Preparation for Use of Supervision TerminalASMi-450Preparatio

Strona 79 - DSP ST SYS [option]

ASMi-450 Control from the Control Port4-6 ASMi-450 Installation and Operation Manual4.4 ASMi-450 Supervision LanguageThis paragraph presents the ASMi

Strona 80 - H<CR>

ASMi-450 Control from the Control PortASMi-450 Installation and Operation Manual 4-7• The address is in the range of 1 through 255 (0 indicates that

Strona 81

ASMi-450 Control from the Control Port4-8 ASMi-450 Installation and Operation ManualTable 4-A. ASMi-450 Command Set IndexCommand Purpose OptionsCLR AL

Strona 82

ASMi-450 Control from the Control PortASMi-450 Installation and Operation Manual 4-94.5 ASMi-450 Command Set DescriptionThis section describes the AS

Strona 83

ASMi-450 Control from the Control Port4-10 ASMi-450 Installation and Operation ManualCLR TST----------------------------------------------------------

Strona 84 - - Single ASMi-450

ASMi-450 Control from the Control PortASMi-450 Installation and Operation Manual 4-114. A typical display, as seen after all the parameters are select

Strona 85 - Control Session

ASMi-450 Installation and Operation Manual viiContentsChapter 1 Introduction1.1 Functional Description...

Strona 86 - Ending a Control

ASMi-450 Control from the Control Port4-12 ASMi-450 Installation and Operation Manual2. The ASMi-450 displays the node name entry form:ENTER NODE NAME

Strona 87

ASMi-450 Control from the Control PortASMi-450 Installation and Operation Manual 4-132. The password entry screen appears, e.g.:NEW PASSWORD (4 to 8 C

Strona 88

ASMi-450 Control from the Control Port4-14 ASMi-450 Installation and Operation ManualNotesIn addition to the parameters listed in Section 3-5, the fol

Strona 89 - Diagnostics

ASMi-450 Control from the Control PortASMi-450 Installation and Operation Manual 4-15DEF SYS----------------------------------------------------------

Strona 90

ASMi-450 Control from the Control Port4-16 ASMi-450 Installation and Operation Manual Terminal Type TV- 920 VT-52 VT-100 Freedom-110 Freedom-220Cl

Strona 91

ASMi-450 Control from the Control PortASMi-450 Installation and Operation Manual 4-17Table 4-B. Control Terminal Alarm MessagesAlarm No. Alarm Syntax

Strona 92

ASMi-450 Control from the Control Port4-18 ASMi-450 Installation and Operation ManualTable 4-2. Control Terminal Alarm Messages (Cont’d)Alarm No. Alar

Strona 93

ASMi-450 Control from the Control PortASMi-450 Installation and Operation Manual 4-19Table 4-2. Control Terminal Alarm Messages (Cont’d)Alarm No. Alar

Strona 94 - 5.3 Test Functions

ASMi-450 Control from the Control Port4-20 ASMi-450 Installation and Operation ManualDisplayFormatA typical HDSL line status display is shown below.ST

Strona 95 - Operating

ASMi-450 Control from the Control PortASMi-450 Installation and Operation Manual 4-21on the remote unit.REMOTE UNIT Displays the state of the loopback

Strona 96 - 5.4 Power-Up Self-Test

Contentsviii ASMi-450 Installation and Operation ManualOrganization of ASMi-450 Display...

Strona 97

ASMi-450 Control from the Control Port4-22 ASMi-450 Installation and Operation ManualF----------------------------------------------------------------

Strona 98

ASMi-450 Control from the Control PortASMi-450 Installation and Operation Manual 4-23INIT DB ---------------------------------------------------------

Strona 99 - Connector Wiring

ASMi-450 Control from the Control Port4-24 ASMi-450 Installation and Operation ManualLOOP-------------------------------------------------------------

Strona 100

ASMi-450 Control from the Control PortASMi-450 Installation and Operation Manual 4-25RESET -----------------------------------------------------------

Strona 101 - A.2 V.35 DCE Connector

ASMi-450 Control from the Control Port4-26 ASMi-450 Installation and Operation Manual4.6 Control Terminal Operating InstructionsBefore using the cont

Strona 102 - A.3 X.21 DCE Connector

ASMi-450 Control from the Control PortASMi-450 Installation and Operation Manual 4-27NoteWhile the control terminal is in session with the ASMi-450, t

Strona 103 - A.4 HDSL Line Connector

ASMi-450 Control from the Control Port4-28 ASMi-450 Installation and Operation Manual• When you see the correct and complete command in the echo line

Strona 104

ASMi-450 Control from the Control PortASMi-450 Installation and Operation Manual 4-294.7 Configuration Error MessagesThe ASMi-450 provides configurat

Strona 105 - SNMP Management

ASMi-450 Control from the Control Port4-30 ASMi-450 Installation and Operation ManualNotes

Strona 106 - B.2 SNMP Environment

ASMi-450 Installation and Operation Manual 5-1Chapter 5Diagnostics5.1 GeneralThe ASMi-450 diagnostics functions include:• Status indications and mess

Strona 107

ContentsASMi-450 Installation and Operation ManualixActivating the Test Functions from a Control Terminal...

Strona 108 - Management

Diagnostics5-2 ASMi-450 Installation and Operation ManualTable 5-A. ASMi-450 Alarm Buffer MessagesMessage Description Corrective ActionsAlarmTypeLAN N

Strona 109

DiagnosticsASMi-450 Installation and Operation Manual 5-3Table 5-1. ASMi-450 Alarm Buffer Messages (Cont’d)Message Description Corrective ActionsAlarm

Strona 110 - B.3 IP Environment

Diagnostics5-4 ASMi-450 Installation and Operation ManualTable 5-1. ASMi-450 Alarm Buffer Messages (Cont’d)Message Description Corrective ActionsAlarm

Strona 111

DiagnosticsASMi-450 Installation and Operation Manual 5-5Table 5-1. ASMi-450 Alarm Buffer Messages (Cont’d)Message Description Corrective ActionsAlarm

Strona 112 - B.4 SNMP Traps

Diagnostics5-6 ASMi-450 Installation and Operation Manual5.3 Test FunctionsTest FunctionsThe ASMi-450 supports the following types of test functions:•

Strona 113 - Appendix C

DiagnosticsASMi-450 Installation and Operation Manual 5-7LOOP REM REM PORTWhen the remote user's port loopback is activated, the user's port

Strona 114

Diagnostics5-8 ASMi-450 Installation and Operation Manual(Cont’d)Step Action Key Display4 Bring the cursor under the left-hand field inthe second row,

Strona 115 - Preparations

DiagnosticsASMi-450 Installation and Operation Manual 5-95.5 Troubleshooting InstructionsIn case a problem occurs, check the displayed alarm messages

Strona 116 - Fastening the Two

Diagnostics5-10 ASMi-450 Installation and Operation ManualTable 5-2. Troubleshooting Chart (Cont’d)No. Trouble Symptoms Probable Cause Corrective Meas

Strona 117

ASMi-450 Installation and Operation Manual A-1Appendix AConnector WiringA.1 RS-530 DCE Connector and Adapter CablesWhen the ASMi-450 is ordered with

Komentarze do niniejszej Instrukcji

Brak uwag