RAD Data comm Vmux-210 Dokumentacja Strona 165: Displaying the Active Tests
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
Installation and Operation Manual
Chapter 6 Troubleshooting and Diagnostics
Vmux-210 Ver. 1.1
Frequently Asked Questions
6-23
�
1100 Hz (CNG) will cause the Vmux-210 to switch into fax-relay mode
(if fax relay is enabled).
�
2100 Hz (fax/modem CED) will cause the Vmux-210 to switch into VBD
(if modem relay is enabled).
Important: The above tones may be detected in the range of +/- 50 Hz
(e.g. 1080 Hz can be detected as 1100 Hz). Therefore when testing voice
frequency across Vmux-210, you should AVOID the following frequency
ranges: 1050-1150 Hz, 1950-2150 Hz.
Q: Pressing the Flash button of the telephone set connected to the FXS port of
the Vmux-210 does not result in the expected function of the PBX/PSTN.
What is the problem?
A: The problem could be related to the Vmux-210 FXS ports setting.
The Flash signal is actually a short on-hook signal, used for many kinds of
PBX/PSTN features. For example, in the call-waiting feature, during an
ongoing conversation, pressing the flash will switch the subscriber to a
waiting call.
Another example is the conference call. A subscriber engaged in a call can
press the Flash button in order to put his remote party on hold and to call a
second remote party. Once the second remote party answers the call,
pressing the flash again will create a bridge enabling the three parties to have
a conference call.
You can define the period of an On-hook/Off-hook action that will be
recognized by the Vmux-210 as a Flash.
�
From the Main Menu select Configuration -> Physical Ports -> Analog ->
Timeouts
The following screen appears:
Timeouts
---------
1. Ring Timeout (sec)[60 - 600]... (120)
2. On hook duration in Flash (msec)[10 - 2000]... (700)
Option number 2 is the on-hook duration for the Flash. The default value
is 700 msec, meaning that during a call, if an on-hook state lasts between
0 and 700 msec, it will be handled as a Flash and the call will not be
disconnected.
Q: What is the meaning of the fragmentation function in the Vmux-210?
A: By default, voice packets get priority over data packets arriving from the LAN
user port. The transmission of frames through the main link (E1/T1/Serial
only) is made in accordance with their priority. However, the prioritization
mechanism cannot ensure a low transmission delay in case a high-priority
packet (voice) arrives after the transmission of a long, lower priority packet
(data) has begun.
Plik PDF · ·
Pytania o RAD Data comm Vmux-210
Nie ma jeszcze pytań o tę instrukcję. Zadaj pierwsze.
Powiązane produkty i podręczniki dla Bramy / kontrolery RAD Data comm Vmux-210
- Bramy / kontrolery RAD Data comm IPmux-24 Instrukcja Użytkownika
(8 stron) - Bramy / kontrolery RAD Data comm MPW-1 Informacje Techniczne
(15 stron) - Bramy / kontrolery RAD Data comm FLM-1 Podręcznik Użytkownika
(401 stron) - Bramy / kontrolery RAD Data comm IPmux-1E Dokumentacja
(143 strony) - Bramy / kontrolery RAD Data comm IPmux-24 Instrukcja Użytkownika
(8 stron) - Bramy / kontrolery RAD Data comm Vmux-210 Instrukcja Użytkownika
(6 stron) - Bramy / kontrolery RAD Data comm ACE-3600 Instrukcja Użytkownika
(8 stron) - Bramy / kontrolery RAD Data comm TDMoIP Gateway IPmux-16 Dokumentacja
(117 stron) - Bramy / kontrolery RAD Data comm ACE-3600 Instrukcja Właściciela
(164 strony) - Bramy / kontrolery RAD Data comm Vmux-210 Instrukcja Użytkownika
(6 stron) - Bramy / kontrolery RAD Data comm TDMoIP Gateway IPmux-16 Instrukcja Użytkownika
(6 stron) - Bramy / kontrolery RAD Data comm IPmux-216 Instrukcja Użytkownika
(8 stron) - Bramy / kontrolery RAD Data comm IPmux-216 Instrukcja Użytkownika
(12 stron) - Bramy / kontrolery RAD Data comm IPmux-11 Instrukcja Użytkownika
(6 stron) - Bramy / kontrolery RAD Data comm IPmux-11 Dokumentacja
(148 stron) - Bramy / kontrolery RAD Data comm MPW-1 Dokumentacja
(108 stron) - Bramy / kontrolery RAD Data comm IPmux-24 Dokumentacja
(190 stron) - Bramy / kontrolery RAD Data comm TDMoIP Gateway IPmux-16 Dokumentacja
(99 stron) - Bramy / kontrolery RAD Data comm Vmux-210 Instrukcja Użytkownika
(12 stron) - Bramy / kontrolery RAD Data comm TDMoIP Gateway IPmux-16 Informacje Techniczne
(90 stron)