TDMoIP Gateway
IPmu
-8
DIAGNOSTICS & MANAGEMENT
• IPmux-8 supports E1/T1 remote
loop and local loop testing.
End-to-end alarm generation and
end-to-end AIS indication are also
provided. If a local E1/T1 port
receives AIS, it is passed to the
remote port via the Ethernet/IP
network. If a local Ethernet port is
not connected, AIS indication will
be generated both in the local and
the remote devices.
• SES and UAS statistics are
collected in 15-minute intervals
on the E1/T1 ports, and are stored
for 24 hours (96 intervals). E1/T1
physical layer alarms (LOS, AIS,
LOF, LCV) are also supported.
• IPmux-8 monitors Ethernet and IP
layer network condition statistics,
such as packet loss and packet
delay variation (jitter). The events
are stored in log files and SNMP
traps are generated.
• IPmux-8 performs an internal
built-in test (BIT) after power-up.
The results of the test are visible
via the local terminal.
• Software download is supported
via the local terminal using
XMODEM, or remotely, using
TFTP. After downloading a new
version of software, IPmux-8
automatically saves the previous
version in non-volatile memory for
backup purposes. Similarly, copies
of the configuration file may be
downloaded and uploaded to a
remote workstation for backup
and restore purposes.
• IPmux-8 can be configured and
monitored locally via an ASCII
terminal, or remotely via Telnet or
RADview.
• RADview-HPOV, RAD’s
SNMP-based network
management system, with its
user-friendly GUI, allows
monitoring and configuring
multiple IPmux devices. Fault
isolation, statistics and events
gathering are available.
RADview-HPOV can hold a
complete predefined IPmux-8
configuration to shorten and
simplify field installation.
• The RADview Service Center and
Element Manager package
supplies and monitors TDMoIP
devices and circuits. The Service
Center’s intuitive GUI
“point-and-click” functionality and
easy-to-follow wizards increase
the efficiency and accuracy of the
service provisioning process.
SPECIFICATIONS
ETHERNET INTERFACE
• Ports
1 per module, up to two modules
• Standards
IEEE 802.3, 802.3u
• Data Rate
10 or 100 Mbps, full duplex
• Range
Up to 100m on UTP Cat.5
• Connector
RJ-45, 8-pin
• Fiber Optic
Range: See Table 2
Connector: LC
E1 INTERFACE
• Ports
4 ports per module, up to two
modules (see Ordering)
• Standards
ITU-T Rec. G.703, G.704, G.706,
G.732, G.823
• Framing
Unframed, CRC4 MF, CAS MF
• Data Rate
2.048 Mbps
• Line Code
HDB3
• Receive Level
0 to -20 dB with LTU
0 to -10 dB without LTU
• Transmit Level
Balanced: ±3V ±10%
Unbalanced: ±2.3V ±10%
• Connector
Balanced: RJ-45, 8-pin
Unbalanced: RJ-45, 75Ω (adapter
cables from RJ-45 to BNC are
supplied)
• Line Impedance
Balanced: 120Ω
Unbalanced: 75Ω
• Jitter Performance
Per ITU-T G.823
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610